Description
POOL PUMP Inverter Aquagem InvereCo DE-22 (1.0KW)
Product Description
Ultra-Efficient & Quiet for Pools up to 75,000L
Upgrade to the Aquagem InverECO DE-22 inverter pool pump. With a 1.0kW motor, ultra-quiet operation, and intelligent energy-saving control, it’s ideal for large pools up to 75,000L.
Heavy-Duty Performance with Whisper-Quiet Efficiency
The Aquagem InverECO DE-22 Inverter Pool Pump is your go-to solution for powerful, eco-conscious pool circulation. Designed for larger pools up to 75,000 litres, this 1.0kW smart inverter pump delivers unmatched energy efficiency, quiet operation, and fully customizable control.
Thanks to Aquagem’s proprietary InverSilence® technology, the DE-22 adapts to your pool’s real-time needs by adjusting its motor speed from 30% to 100%, helping you save up to 90% in energy costs. The IE4-rated motor is engineered for long-term durability, high efficiency, and low noise—perfect for residential or semi-commercial applications.
With a flow rate of 22m³/h @ 8m head and intelligent full-touch control panel, the DE-22 allows you to schedule up to 4 operating timers per day, optimize energy use, and trigger one-touch backwashing with 100% boost power.
Technical Specifications:
| Feature | Value |
|---|---|
| Model | InverECO DE-22 |
| Recommended Pool Size | 50,000L – 75,000L |
| Power Rating | 1.0 kW |
| Voltage | 220–240V, 50/60Hz |
| Max Flow Rate (Qmax) | 25.0 m³/h |
| Max Head (Hmax) | 17.0 m |
| Flow @ 8m Head | 22.0 m³/h |
| Flow @ 10m Head | 18.0 m³/h |
| Motor Class | IE4 (High Efficiency) |
BENEFITS
-
-
For Larger Pools: Designed to efficiently handle pools up to 75,000 litres.
-
Energy Saving Champion: Up to 90% less electricity than traditional pumps.
-
Ultra Quiet: As low as 38 dB—ideal for peaceful poolside enjoyment.
-
Smart Touchscreen Controller: Full speed control, real-time power readings, and 4 programmable timers.
-
Boost Mode: One-touch 100% power for backwash and high-demand operations.
-
Soft Start Technology: Extends pump lifespan by gradually ramping power.
-
Flexible Control: Compatible with external timers or digital control systems.
-
✅ Inverter-Driven Efficiency – Saves up to 80% on energy compared to single-speed pumps
✅ Quiet Operation – Operates as low as 36dB for peaceful poolside enjoyment
✅ Smart Controller – Easy-to-use touch interface with daily timers and backwash function
✅ Extended Durability – Soft-start feature reduces mechanical stress and wear
✅ Eco-Conscious – Reduced CO₂ footprint, perfect for green-conscious pool owners
BOX CONTENTS
-
1 x Aquagem InverECO DE-22 Inverter Pool Pump
-
1 x Intelligent Full-Touch Controller
-
2 x 63mm Unions
-
2 x 63mm/50mm PVC Reducers
-
1 x Pump Lid Spanner
-
1 x Touchscreen Protector
-
1 x Communication Cable
-
1 x User Manual
Frequently Asked Questions (FAQ)
Q: What pool size does the DE-22 support?
A: The DE-22 is best suited for pools between 50,000 and 75,000 litres.
Q: How quiet is the operation?
A: It operates at sound levels as low as 38 dB—up to 20x quieter than most conventional pumps.
Q: Can I schedule it to run at different speeds during the day?
A: Yes! The built-in touchscreen allows up to 4 custom timers with varying speeds.
Q: Does it support backwashing?
A: Definitely. Use the one-touch “Boost” feature to instantly ramp up to 100% speed for backwash.
Q: Is it energy efficient?
A: Yes. The IE4-rated motor and inverter tech help save up to 90% energy compared to single-speed pumps.
Installation Instructions:
We recommend that the pump is installed by a qualified pool professional or electrician.
A good installation of your pool pump will result in many years of trouble-free operation. Careful attention must be paid to the following:
1. Piping: The suction and discharge pipes must not be smaller in diameter than the pump connection i.e., Suction pipe diameter 50mm minimum (recommended 63mm), outlet pipe diameter 50mm minimum. Suitable unions should be used on the pump connections or placed in the lines adjacent to the pump connections in case the pump needs to be removed at any time. Do not support the pipework on the pump or vice versa. Make sure all pipe connections are completely water/airtight by using a suitable pipe jointing compound. Keep suction pipe as short as possible and only use pipes that are sufficiently rated to work at a minimum of 4 bar pressure. The suction line should enter the pump straight and horizontally for a length of at least 4 x the diameter of the pipe. The pump is a self-priming pump, which can be installed above or below water level, if you choose to go below, be sure to connect a control valve on your suction pipe between the pool weir/skimmer and the pump, which will prevent your pump being flooded when you open the lid to clean the pump leaf basket. Do not over tighten fittings into the inlet and outlet of the pump. Position pump on a flat level surface not exposed to flooding, as the pump motor is not waterproof.
2. Pump Positioning: (Important for motor cooling): We recommend that the pump be positioned at a level of no more than ± 300mm above your pool water level. Again, we stress the fact to keep the suction line as short as possible. A minimum clearance of 150mm must be allowed behind the motor fan cowling to the nearest obstruction to ensure proper air ventilation and easy access for servicing. The pump house/box must also have provision for adequate drainage facilities.
3. Ventilation: As the electric motor is fan cooled, sufficient ventilation must be allowed at all times during operation. Failure to do this will cause overheating resulting in premature bearing failure and/or motor burnout. If your pump house/box does not have ventilation holes the lid or door should be left open during operation of the pump.
4. Drainage: Flooding of the electric motor is the most common cause of motor failure. It is essential that adequate drainage be provided in the pump house/box. If the motor fails as a result of flooding, then there is no warranty whatsoever irrespective of how the water penetrated the motor. The pump must be protected from rain and flooding.
5. Electric Connections: These must be carried out by suitably qualified people only. Do not change the motor position as it is provided with a drain hole at the bottom to drain off any water which may leak past the mechanical shaft seal. A cable gland must be fitted to the terminal box. NOTE: The length of cable supplied with the pump is for testing only and should be replaced with suitably rated cable. Minimum specification 60245IEC66 (HO7RN-F).
6. Rotation: Before checking the rotation, drain the pump leaf trap of water. The correct rotation is clockwise when viewed from the motor end. Pumps with 220-volt single phase motors are wired at the manufacturer for the correct rotation.
How to keep your pool pump in good running condition
1. Clean the leaf trap in the pump and pool weir regularly.
2. Do not allow dust to accumulate on the motor as this affects the cooling process.
3 Do not leave foreign objects lying on the motor.
4 Change the rubber 0-Ring in the lid at 1-year intervals to maintain a good seal. The face on the leaf trap where the 0-Ring sits must be kept clean and smooth.
6. DO NOT RUN THE PUMP DRY or under closed valve conditions for extended periods.
7. Backwash your filter once a week, or when the pressure exceeds 50% above the starting operating pressure.
8. No Vaseline or petroleum-based lubricants should be used for lubricating 0-Rings or seals. Only silicone paste should be used.
Warranty Information:
5 year Warranty
.Should a defect become evident during the term of the warranty, at its option, the manufacturer will repair
or replace such item or part at its own cost and expense. Customers need to follow the warranty claim
procedure in order to obtain the benefit on this warranty.
The guarantee will be void in cases of improper installation, improper operation, inappropriate use,
tampering or using non-original spare parts.














Reviews
There are no reviews yet.